(Created page with "== Status == <onlyinclude> * '''Works great''' * '''http://prusa-mini-1.in.hacklab.to/''' </onlyinclude> ----- Last Known Good Settings {| cellpadding="5" cellspacing="0" border="1" !Date !Filament type, colour, brand !First layer !Other layers !Notes |- | | | | |- |} == Maintenance Log == Most recent entries at the top. {| cellpadding="5" cellspacing="0" border="1" !Date !Notes !Entry By |- | May 24th, 2025 | Enabled Filament Sensor, as it was disabled and the lack...")
 
No edit summary
 
Line 1: Line 1:
== Status ==
== Status ==
<onlyinclude>
<onlyinclude>
* '''Works great'''
* '''Solid Workhorse'''
* '''http://prusa-mini-1.in.hacklab.to/'''
* '''http://octopi4.in.hacklab.to/'''
</onlyinclude>
</onlyinclude>


Line 31: Line 31:
| May 24th, 2025
| May 24th, 2025
|
|
Enabled Filament Sensor, as it was disabled and the lack of run-out detection ruined a 14-hour print.
* Discovered filament sensor disabled in menu.
|  
* Investigation show the sensor mechaism sticking in the 'filament present' position.
* Disassembled E-Axis assembly. https://help.prusa3d.com/guide/5-e-axis-assembly_28536#28816
* Magnet in the FS-lever had migrated out of it's seated position resulting in it rubbing against the inside of the assembly body. Reseated the magnet.
* Tightened set screw for heater cartridge in heater block.
* Preformed XYZ Calibration.
* Preformed First Layer Calibration.
| [User:Revident]
|-
|-

Latest revision as of 21:48, 24 May 2025

Status



Last Known Good Settings

Date Filament type, colour, brand First layer Other layers Notes

Maintenance Log

Most recent entries at the top.

Date Notes Entry By
May 24th, 2025
  • Discovered filament sensor disabled in menu.
  • Investigation show the sensor mechaism sticking in the 'filament present' position.
  • Disassembled E-Axis assembly. https://help.prusa3d.com/guide/5-e-axis-assembly_28536#28816
  • Magnet in the FS-lever had migrated out of it's seated position resulting in it rubbing against the inside of the assembly body. Reseated the magnet.
  • Tightened set screw for heater cartridge in heater block.
  • Preformed XYZ Calibration.
  • Preformed First Layer Calibration.