== Problems ==
== Troubleshooting ==


* Currently experiencing a MINTEMP error.
* Were experiencing a MINTEMP error.
 
** Manually adding M302 (enable cold extrusion) into the start gcode in CURA,
Attempted to insert M302 (enable cold extrusion) into the start gcode in CURA. didn't work.  Asked the [[http://forum.structur3d.io/ structur3d.io forum]], received [[http://forum.structur3d.io/t/enabling-cold-extrusion-avoiding-mintemp-erroe/321 this reply]]... I don't have sufficient clue to talk gcode directly to the printer at this stage of my 3dp learnings so I'm deferring to someone more expert in these sorts of things things...
** Commenting out / removing any M109 set temperature commands, and
 
** Plugging in an extruder thermocouple to read out _some_ temperature (as would otherwise encounter a MINTEMP error, code 0, preventing the print from starting). Had Asked the [[http://forum.structur3d.io/ structur3d.io forum]], received [[http://forum.structur3d.io/t/enabling-cold-extrusion-avoiding-mintemp-erroe/321 this reply]]... Need to update the forum with our methods to overcome the error.
* [[http://forum.structur3d.io/t/um2-wiring-advice-gcode-modification-using-cura/303 here's another forum post]] with some other settings to try...
* Extrusion speed needs modification
** [[http://forum.structur3d.io/t/um2-wiring-advice-gcode-modification-using-cura/303 here's another structur3d forum post]] with some other recommended settings for enabling cold extrusion, along with changing extrusion feed rates.
** removed some extrusion step multipliers from the extrusion hardware, such that sending code "G1 F18000 E270" via pronterface would pretty much result in one full rotation of the large white gear underneath the extruder.
** Need to determine how much volume that equates to coming out of the 50ml syringe, and adjust feed settings appropriately to extrude proper amounts. We were definitely experiencing some delay / leaky extrusion following a period of extrusion from the syringe, may be due to high pressures required to force viscous paste through the extruder, and /or perhaps bulging of the tubing with a step increase in pressure, which may cause more extrusion down the line.


== Stuff to extrude ==
== Stuff to extrude ==
Line 27: Line 30:
* Various edible things
* Various edible things
* ... other?  Happy to field suggestions...
* ... other?  Happy to field suggestions...
== To Dos ==
Some plans / to dos for the future:
* Insert some sort of pressure sensor / transducer in line with the extruder, to monitor changes in pressure in the lines, and maybe figure out if there's any weird viscoelastic coupling we need to be dealing with with regards to the delay in between extrusion pumo going and stuff coming out the extrusion nozzle. May require some fancy extruder retraction code if there's a complex temporal relationship between extrusion, pressure in the syringe, and pressure in the line/nozzle...
* Figure out appropriate feed rates
* maybe figure out a less viscous test material - had to press pretty vigorously on the syringe to force the caulk through the lines...
* ...
== Pictures! ==
Pictures and a video of the setup are available at [[https://www.flickr.com/gp/tdmckee/1oCv88 this flickr album]]