→Machine Log: Update for rest of the work done last week.
(→Status: update for additional work done.) |
(→Machine Log: Update for rest of the work done last week.) |
||
Line 177: | Line 177: | ||
| | | | ||
* STILL GETTING '''LARGE''' X-AXIS SHIFTS! | * STILL GETTING '''LARGE''' X-AXIS SHIFTS! | ||
** Next week, I | ** Next week, I may have to check that both stepper drivers are at the below voltages. (To make sure I didn't adjust the wrong driver board pot.) | ||
* Moving the Head back & forth along the X-Axis (with the power off), it seems to be catching/binding as it goes side-to-side. | |||
* Ajust the X-Axis right pully screw '''again'''. (Slowly tightening it this time.) | |||
** After several tries to adjust this, the X belt suddenly has good tension again, and the head now moves smoothly side-to-side. | |||
** Then was able to get a multi-hour print that came out perfectly, with no layer shift. ... So this might finally be fixed. | |||
|Allen | |Allen | ||
|- | |- | ||
Line 185: | Line 189: | ||
* The Y axis REF voltage was upped from 0.316V to 0.368V. | * The Y axis REF voltage was upped from 0.316V to 0.368V. | ||
** This should correspond to a current increase from 250mA to 295mA. | ** This should correspond to a current increase from 250mA to 295mA. | ||
* Use SuperLube to carefully lubricate all the rods & the Z-axis screw. | |||
|Allen | |Allen | ||
|- | |- |