Ultimaker 1: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 11: | Line 11: | ||
!Notes | !Notes | ||
!Entry By | !Entry By | ||
|- | |||
|April 29, 2013 | |||
|Printed and installed new extruder feed gear to reduce backlash during retraction.<br/> | |||
Observed inconsistent extrusion. Small gaps appearing in extrusion, yet full infill occurring on layers otherwise (ie: not clogged).<br/> | |||
Investigation pointing towards slipping knurled bolt in feeder, or more likely, old wet PLA causing problems. | |||
|Norm | |||
|- | |- | ||
Revision as of 11:52, 30 April 2013
This page documents Ultimaker #1 (Guy)
Status
- This Ultimaker is currently functional and in reasonable to good condition!
Machine Log
Date | Notes | Entry By |
---|---|---|
April 29, 2013 | Printed and installed new extruder feed gear to reduce backlash during retraction. Observed inconsistent extrusion. Small gaps appearing in extrusion, yet full infill occurring on layers otherwise (ie: not clogged). |
Norm |
April 27, 2013 | Print quality degraded significantly mid-print. Hot end disassembled, burnt PLA removed from brass tube, and dust/dirt removed from teflon-PEEK interface. Print quality returned to normal. Clogged again, cleaned more thoroughly this time. (Used 1/8" drill bit to handheld scrape out burnt PLA very carefully. PLA diameter changed. |
Norm |
April 24, 2013 | Squeaking noise observed from Y axis axle. Endcap inset screw noticed to be loose, requires new endcap to be printed, and screw not to be overtightened. |
Norm |
April 12, 2013 | Bed leveling assist tool printed and built. | Norm |
April 8, 2013 | Belts retensioned, new bearing endcaps installed to reduce backlash further. | Norm |
April 6, 2013 | Z axis calibration fixed, Z steps/mm in new profile on Git. X/Y axis backlash observed, infill not meeting walls, delamination observed. |
Norm |
March 31, 2013 | Z axis calibration issues observed. 25mm Test cube showed ~6.8% Z axis error. |
Norm |