Ultimaker 1: Difference between revisions
No edit summary |
No edit summary |
||
Line 84: | Line 84: | ||
|- | |- | ||
|November 13, 2015 | |||
Ultimaker 1 is working, uses 3mm PLA filament. Has also been fitted for ABS use. | |||
|Emmy | |||
|- | |||
Revision as of 14:44, 13 November 2015
This page documents Ultimaker #1 (Guy)
Status
- This Ultimaker is currently functional and in reasonable to good condition!
- It is managed and accessible from the web GUI: http://octopi.hacklab.to/
Machine Log
Date | Notes | Entry By |
---|---|---|
June 8, 2013 | Added tool holder onto side of Ultimaker | Norm |
May 14, 2013 | Tensioned X/Y belts, switched to white PLA and tested new experimental settings. Readjusted Z bed height, printed stuff. | Norm |
May 11, 2013 | Rod endcaps removed, threadlock (blue) applied to the M3 screws and setscrews locked into place to prevent loosening. Lubricated Z axis and gantry system. |
Norm |
May 1, 2013 | Printed and mounted new Z home switch retaining mechanism and calibrated. Z homing much more accurate. Observed further inconsistent extrusion, further investigation found online that the knurled bolt is only useful for the last 3 mm nearest the groove for the delrin clip. Adjusted bolt positioning to move good knurling into position, no further grinding or slipping observed, consistent solid extrusion demonstrated. |
Norm |
April 30, 2013 | Installed new e-panel composite based build platform. | Geordie |
April 29, 2013 | Printed and installed new extruder feed gear to reduce backlash during retraction. Observed inconsistent extrusion. Small gaps appearing in extrusion, yet full infill occurring on layers otherwise (ie: not clogged). |
Norm |
April 27, 2013 | Print quality degraded significantly mid-print. Hot end disassembled, burnt PLA removed from brass tube, and dust/dirt removed from teflon-PEEK interface. Print quality returned to normal. Clogged again, cleaned more thoroughly this time. (Used 1/8" drill bit to handheld scrape out burnt PLA very carefully. PLA diameter changed. |
Norm |
April 24, 2013 | Squeaking noise observed from Y axis axle. Endcap inset screw noticed to be loose, requires new endcap to be printed, and screw not to be overtightened. |
Norm |
April 12, 2013 | Bed leveling assist tool printed and built. | Norm |
April 8, 2013 | Belts retensioned, new bearing endcaps installed to reduce backlash further. | Norm |
April 6, 2013 | Z axis calibration fixed, Z steps/mm in new profile on Git. X/Y axis backlash observed, infill not meeting walls, delamination observed. |
Norm |
March 31, 2013 | Z axis calibration issues observed. 25mm Test cube showed ~6.8% Z axis error. |
Norm |
November 13, 2015
Ultimaker 1 is working, uses 3mm PLA filament. Has also been fitted for ABS use. |
Emmy |