Machine Log
Date | Notes | Entry By |
---|---|---|
April 24, 2013 | Squeaking noise observed from Y axis axle. Endcap inset screw noticed to be loose, requires new endcap to be printed, and screw not to be overtightened. |
Norm |
April 12, 2013 | Bed leveling assist tool printed and built. | Norm |
April 8, 2013 | Belts retensioned, new bearing endcaps installed to reduce backlash further. | Norm |
April 6, 2013 | Z axis calibration fixed, Z steps/mm in new profile on Git. X/Y axis backlash observed, infill not meeting walls, delamination observed. |
Norm |
March 31, 2013 | Z axis calibration issues observed. 25mm Test cube showed ~6.8% Z axis error. |
Norm |