*NO OIL
*NO OIL
*Should be compatible with both ferrous metals and aluminum.
*Should be compatible with both ferrous metals and aluminum.
Recommended: "xtreme cut 250" from torontolube.ca
 
Currently selected coolant:
*Qualichem XTREME CUT 250C
*Source: torontolube.com, Alan at customerservice@torontolube.com - 1 gallon jug is all we need, which is below their minimum quantity - but they made an exception.
*Dilute to 8-10% by adding concentrate to tap water (not the other way around!)
See preventative maintenance
 
 


Good idea: [https://www.reddit.com/r/Machinists/comments/j5vjk1/diy_window_air_blast_for_cnc_lathe/]
Good idea: [https://www.reddit.com/r/Machinists/comments/j5vjk1/diy_window_air_blast_for_cnc_lathe/]
Line 69: Line 76:
**Check coolant level
**Check coolant level
**Remove chips from ways, carriage and bellows
**Remove chips from ways, carriage and bellows
**Agitate coolant with air (todo aquarium pump)
*Long-term
*Long-term
**Check coolant concentration; remove sediment
**Check coolant level and concentration; remove sediment
**Skim coolant to remove oil regularly (oil grows bacteria)
**Check axes are receiving oil, check belts
**Check axes are receiving oil, check belts


Line 80: Line 89:
*TTS - Tormach Tooling System
*TTS - Tormach Tooling System


'''Flood Coolant'''
Qualichem XTREME CUT 250C
Source: torontolube.com, Alan at customerservice@torontolube.com - 1 gallon jug is all we need, which is below their minimum quantity - but they made an exception.
Dilute to 8-10% by adding concentrate to tap water (not the other way around!)
Measure with refractometer and add water regularly to compensate for evaporation
Skim to remove oil regularly (oil grows bacteria)
Agitate with air regularly (todo aquarium pump)


'''Items to purchase'''
'''Items to purchase'''